This website uses cookies to give you the best experience. By using this website you consent to the use of the cookies.
NOVELTYOfferSpecial priceAll out
Search by brand
Search by categories
- Gift card
- Speakers and acc.
- Articles for Christmas
- Audio-video
- Batteries and charger
- Wellness Sport
- DIY
- LOUDSPEAKERS
- Cable
- Electronic components
- CONNECTION
- Containers and suitcases
- DJ - Entertainment
- HOME APPLIANCES-
- Electronics
- POWER-
- HARDWARE
- OFFICE SUPPLIES
- Photo and video
- Hobby and gadgets
- Lighting
- Computer science and console
- ELECTRICAL EQUIPMENT
- Microphones and headphones
- Car products
- Remotemeliters & Acc.
- Voltage reducers
- Earth's satellite and digital
- SAFETY
- Audio diffusion systems
- Remote controls
- Telephony
- Tools and measuring tools
QR Code
Sistema di allarme vocale All-In-One certificato EN54-16 completo di pacco batterie di backup con circuito di ricarica e test EN54-4. Amplificatore principale e di riserva in classe D "Pure Path"™ 300W @ 100V su linea altoparlanti ridondante (A + B). Il sistema garantisce prestazioni complete a piena potenza anche con alimentazione di backup. Circuito di processamento mediante DSP; ingresso musica di sottofondo bilanciato e isolato, ingresso microfonico isolato dotato di alimentazione phantom 48V selezionabile e attivazione della priorità mediante contatto; ingresso monitorato per postazioni di chiamata d'emergenza remote; pannello frontale equipaggiato di: altoparlante monitor, microfono PPT di emergenza monitorato, tasti di invio diretto dei messaggi, tasti di navigazione , ampio display a matrice di punti LCD e chiave di attivazione utente; uscita di linea per sub-woofer attivo; messaggi audio memorizzabili su uSD 16 bit 48Khz: 8 messaggi di uso generale con attivazione da contatti di ingresso dedicati o da scheduler incorporato, 2 contatti monitorati per attivazione annunci di emergenza.
ModelAE300
Main power sourceAC mains 220V - 50/60Hz
Backup power source48V – built-in batteries (4x 12V 7,2A/h sealed lead acid)
Backup power unit life36h stand-by + 0.5h full power
Maximum power consumption350W
Rated Output powerSingle zone 300W rms @ 1% THD on 100V loudspeaker line
Frequency response100Hz – 18Khz @ -3dB
Signal to noise ratio>90dB
Redundant power amplifierYes
Redundant loudspeaker lineYes (Line A, Line B)
Loudspeaker line monitoringLine A and Line B independent 18 KhZ FFT impedance measurement +/-5% range. Detection of line cut, line short, line grounding
User interfaceStatus leds + dot-matrix display, menu navigation keyboard, direct access status keys (alarm, warning, silencing)
Audio processingDSP based, 16bit-48Khz; 3-band equalizer, Compressor/expander on microphone inputs; Pre-gain and master volume controls; Chime
Audio inputs/outputsBackground music; microphone input with phantom supply and enable contact input. Subwoofer line output
Front panel loudspeaker monitorYES
Emergency Firemen microphoneFrontpanel PPT microphone with monitored capsule RJ14 input for WG-MTU01 desktop emergency call station
General input controls8x dry contact inputs triggers for general announcement messages
General message schedulerYES
Input controls from fire alarm devices2x monitored input contacts against cable-cut and cable short. Alarm, warning
Output status reporting 2x 1A 230V relay contacts (alarm, fault)
CommunicationRS485, RS232 diagnostic port, RJ45 10 BASE-T/100
Battery monitoringInternal resistance DC measurement
Certifications and compliancyEN54-16, EN54-4, BS-EN5839-8, 60849
Access restrictionKey-locked front door, password protected access to system menu
Chassiss, dimensions and weightSteel, powder coated – 12Kg batteries included. Width 440mm, Height 11 Rack units (490mm) – Depth 150mm
Main power sourceAC mains 220V - 50/60Hz
Backup power source48V – built-in batteries (4x 12V 7,2A/h sealed lead acid)
Backup power unit life36h stand-by + 0.5h full power
Maximum power consumption350W
Rated Output powerSingle zone 300W rms @ 1% THD on 100V loudspeaker line
Frequency response100Hz – 18Khz @ -3dB
Signal to noise ratio>90dB
Redundant power amplifierYes
Redundant loudspeaker lineYes (Line A, Line B)
Loudspeaker line monitoringLine A and Line B independent 18 KhZ FFT impedance measurement +/-5% range. Detection of line cut, line short, line grounding
User interfaceStatus leds + dot-matrix display, menu navigation keyboard, direct access status keys (alarm, warning, silencing)
Audio processingDSP based, 16bit-48Khz; 3-band equalizer, Compressor/expander on microphone inputs; Pre-gain and master volume controls; Chime
Audio inputs/outputsBackground music; microphone input with phantom supply and enable contact input. Subwoofer line output
Front panel loudspeaker monitorYES
Emergency Firemen microphoneFrontpanel PPT microphone with monitored capsule RJ14 input for WG-MTU01 desktop emergency call station
General input controls8x dry contact inputs triggers for general announcement messages
General message schedulerYES
Input controls from fire alarm devices2x monitored input contacts against cable-cut and cable short. Alarm, warning
Output status reporting 2x 1A 230V relay contacts (alarm, fault)
CommunicationRS485, RS232 diagnostic port, RJ45 10 BASE-T/100
Battery monitoringInternal resistance DC measurement
Certifications and compliancyEN54-16, EN54-4, BS-EN5839-8, 60849
Access restrictionKey-locked front door, password protected access to system menu
Chassiss, dimensions and weightSteel, powder coated – 12Kg batteries included. Width 440mm, Height 11 Rack units (490mm) – Depth 150mm
Feedback
Shopping cart
Shopping cart is empty
Last watched
Utenti in linea:
190
Feedback
- 21.02.2024 SCASamsung replacement TV remote control with compatible Smart TV functions
Ottimo venditore, il prodotto è arivato velocemente in condizioni pefette. Consigliatissimo
- 17.11.2023 EMM
TUTTO OK
- 14.03.2023 ELI
Ottimo venditore, veloce e preciso, consigliato.